Berlangganan saluran Walrus

Superpump all in one - pompa booster HQ Walrus

20 Februari 2020

Bab Bab (You may choose either section)

00:39Memperkenalkan perusahaan Walrus

CEO Walrus Amy Huang berbicara tentang sejarah dan filosofi perusahaan

03:55Pengembangan pompa pendorong

Wakil Presiden Samuel Huang berbicara tentang berbagai generasi pompa pendorong dari tahun 1984 hingga saat ini.

08:01Kinerja langsung HQ 400

Perbandingan langsung pompa booster HQ 400 dengan model sebelumnya - menghasilkan aliran air dan kebisingan

10:58Fitur pompa booster seri HQ

Simon Yen,manajemen dep penjualan internasional. jelaskan fitur unik dari HQ Line Collisions

16:58Pemasaran walrus

Mark Lin, wakil presiden departemen penjualan internasional. bagikan strategi dan tantangan pemasaran Walrus

18:55Testimoni dari distributor Irlandia

Distributor perusahaan di Irlandia berbicara tentang pengalamannya bekerja dengan Walrus

22:52Bagian pertanyaan dan jawaban

Tim Walrus menjawab beberapa pertanyaan paling populer dan menarik terkait dengan perusahaan dan HQ Booster Pumps.

Superpump all in one - pompa booster HQ Walrus

HQ800

HQ800H

Sorotan dari seri HQ

  • Desain all-in-one: pompa, motor, bejana tekan, pengontrol elektronik
  • Desain kompak & sangat sunyi
  • Tidak ada korosi dan umur panjang
  • 20% konsumsi daya lebih rendah

Ngobrol atau hubungi Walrus

Bicara sekarang dengan Walrus di Messenger

Mengirim pesan Perwakilan Penjualan Internal. Simon Yen pompa Walrus. Dia akan segera kembali kepada Anda!

Tautan

Belajar lebih tentang Pompa Walrus disini.

WALRUS Daftar pompa booster HQ

(before operation, turn off power switch first.)

HQ TQ Series

Cause 1: No power supply. Remedy: Connect the electricity supply.

Cause 2: Too low/high voltage. Remedy: Check if supply voltage is within ± 10%.

Cause 3: Seized-up pump. Remedy:Place a screwdriver against the shaft end of the motor to check it the rotor will spin freely,and contact your pump supplier.

Cause 1: Seized-up pump. Remedy: Same as above.

Cause 2: Overloaded motor. Remedy: Turn off the power supply and restart or contact your pump supplier.

Cause 3: Poor water supply. Remedy: Check if pump suction inlet is blocked.

Cause 1: Existing pipe is leaking. Remedy: Fix the leakage.

Cause 2: Defective check valve. Remedy: Clean or replace with a new valve.

Cause 3: Pipe suck in air. Remedy: Check the suction pipe and water supply.

Cause 1: Leakage in suction pipe or air in the water. Remedy: Check the suction pipe and water supply.

Cause 2: Discharge flow is too low. Remedy: Set your tap on a higher water flow.

Ineffective grounding. Remedy: Reactivate grounding.

Cause 1: Poor water supply or air suck in. Remedy: 1. Turn off the power supply and open the refilling plug to release the air. Then restart.2. In case of long suction pipes, turn off the power and make sure if water supply is adequate.

Cause 2: Pressure set is too high. Remedy: Adjust pressure per XI.

Cause 3: Flow set is too small. Remedy: Adjust flow switch per XII.

Cause 1: 3-phase motor runs in wrong rotation. Remedy: Switch any of the 2 wires from motor terminal to correct rotation.

Cause 2: Poor water supply. Remedy: check if water supply is adequate and if the suction pipe is blocked.

TP8-PT Series

Cause: The overheating protector is mounted directly on the motor windings. It will stop the motor automatically when the motor temperature is up to abnormal, and restart the motor after the temperature back to normal in 20 minutes.

Remedy:

  • Check the electrical power source, fuse, and circuit breaker.
  • Check if pump is locked by rust or foreign objects.
  • Check if the ventilation of the location is bad for causing the overheating of motor.

Remedy: a. Check and fix the leakage in discharge piping, faucets, and valves.

Cause: The pump's pressure switch has been set accurately. Please do not try to adjust except by qualified personnel.

Remedy:

  • If the motor does not start after any of the faucets or valves are opened, adjust the pressure setting screw to the "+" direction (counterclock- wise) until the motor starts.
  • If the motor fails to stop after all the faucets and valves are closed, adjuts the pressure setting screw to the "-" direction (clockwise) until the motor stops.
  • Repeat step (a) and (b) until the pump work normally.

TP3-PT Series

Cause: The overheating protector is mounted directly on the motor windings. It will stop the motor automatically when the motor temperature is up to abnormal, and restart the motor after the temperature back to normal in 20 minutes.

Remedy:

  • Check the electrical power source,fuse,and circuit breaker.
  • Check if pump is locked by rust or foreign objects.
  • Check if the ventilation of the location is bad for causing the overheating of motor.

Remedy:

  • The pump casing should be full of water,if shortage,please open the red water plug and pour into water anew till quite brimming.
  • If water is leaking out from the pipe please install again there's a blockade in the drain-pipe,please clean it out.If you can't get rid of the bug,please call to sales agent or the distributive service station.